Mounting Mode |
Wall mount |
Maximum transient current |
529 A 60 s normal duty) |
581 A 60 s heavy duty) |
Phase |
3 phase |
Discrete output number |
0 |
Discrete output type |
Relay outputs R1A, R1B, R1C 250 V AC 3000 mA |
Relay outputs R1A, R1B, R1C 30 V DC 3000 mA |
Relay outputs R2A, R2C 250 V AC 5000 mA |
Relay outputs R2A, R2C 30 V DC 5000 mA |
Relay outputs R3A, R3C 250 V AC 5000 mA |
Relay outputs R3A, R3C 30 V DC 5000 mA |
Output voltage |
<= power supply voltage |
Permissible temporary current boost |
1.1 x In 60 s normal duty) |
1.5 x In 60 s heavy duty) |
Motor slip compensation |
Automatic whatever the load |
Adjustable |
Not available in permanent magnet motor law |
Can be suppressed |
Acceleration and deceleration ramps |
Linear adjustable separately from 0.01…9999 s |
Physical interface |
Ethernet |
2-wire RS 485 |
Braking to standstill |
By DC injection |
Protection type |
Thermal protection motor |
Safe torque off motor |
Motor phase break motor |
Thermal protection drive |
Safe torque off drive |
Overheating drive |
Overcurrent between output phases and earth drive |
Overload of output voltage drive |
Short-circuit protection drive |
Motor phase break drive |
Overvoltages on the DC bus drive |
Line supply overvoltage drive |
Line supply undervoltage drive |
Line supply phase loss drive |
Overspeed drive |
Break on the control circuit drive |
Transmission Rate |
10, 100 Mbits |
4800 bps, 9600 bps, 19200 bps, 38.4 Kbps |
Frequency resolution |
Display unit 0.1 Hz |
Analog input 0.012/50 Hz |
Transmission frame |
RTU |
Electrical connection |
Control removable screw terminals 0.5…1.5 mm² AWG 20…AWG 16 |
Line side screw terminal 4 x 185 mm² 3 x 350 kcmil |
Motor screw terminal 4 x 185 mm² 3 x 350 kcmil |
Connector type |
RJ45 on the remote graphic terminal)Ethernet/Modbus TCP |
RJ45 on the remote graphic terminal)Modbus serial |
Data format |
8 bits, configurable odd, even or no parity |
Type of polarization |
No impedance |
Exchange mode |
Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP |
Number of addresses |
1…247 Modbus serial |
Method of access |
Slave Modbus TCP |
Supply |
External supply for digital inputs 24 V DC 19…30 V), <1.25 mA overload and short-circuit protection |
Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection |
Internal supply for digital inputs and STO 24 V DC 21…27 V), <200 mA overload and short-circuit protection |
Local signalling |
For local diagnostic 3 LEDs |
for embedded communication status 3 LEDs (dual colour) |
for communication module status 4 LEDs (dual colour) |
for presence of voltage 1 LED (red) |
Width |
23.54 in (598 mm) |
Height |
47.05 in (1195 mm) |
Depth |
14.96 in (380 mm) |
Net Weight |
447.54 lb(US) (203 kg) |
analogue input number |
3 |
Analogue input type |
AI1, AI2, AI3 software-configurable voltage 0…10 V DC 31.5 kOhm 12 bits |
AI1, AI2, AI3 software-configurable current 0…20 mA 250 Ohm 12 bits |
AI2 voltage analog input – 10…10 V DC 31.5 kOhm 12 bits |
Discrete input number |
8 |
Discrete input type |
DI7, DI8 programmable as pulse input 0…30 kHz, 24 V DC <= 30 V) |
Input compatibility |
DI1…DI6 discrete input level 1 PLC IEC 61131-2 |
DI5, DI6 discrete input level 1 PLC IEC 65A-68 |
STOA, STOB discrete input level 1 PLC IEC 61131-2 |
Discrete input logic |
Positive logic (source) DI1…DI8), < 5 V, > 11 V |
Negative logic (sink) DI1…DI8), > 16 V, < 10 V |
analogue output number |
2 |
Analogue output type |
Software-configurable voltage AQ1, AQ2 0…10 V DC 470 Ohm 10 bits |
Software-configurable current AQ1, AQ2 0…20 mA 10 bits |
Software-configurable current DQ-, DQ+ 30 V DC |
Software-configurable current DQ-, DQ+ 100 mA |
Sampling duration |
2 ms +/- 0.5 ms DI1…DI4) – discrete input |
5 ms +/- 1 ms DI5, DI6) – discrete input |
5 ms +/- 0.1 ms AI1, AI2, AI3) – analog input |
10 ms +/- 1 ms AO1) – analog output |
Accuracy |
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input |
+/- 1 % AO1, AO2 for a temperature variation 60 °C analog output |
Linearity error |
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input |
AO1, AO2 +/- 0.2 % analog output |
Relay output number |
3 |
Relay output type |
Configurable relay logic R1 fault relay NO/NC 100000 cycles |
Configurable relay logic R2 sequence relay NO 100000 cycles |
Configurable relay logic R3 sequence relay NO 100000 cycles |
Refresh time |
Relay output R1, R2, R3)5 ms +/- 0.5 ms) |
Minimum switching current |
Relay output R1, R2, R3 5 mA 24 V DC |
Maximum switching current |
Relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC |
Relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC |
Relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC |
Relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC |
Isolation |
Between power and control terminals |
Maximum output frequency |
500 kHz |
Maximum Input Current per Phase |
451.0 A |
Variable speed drive application selection |
Building – HVAC compressor centrifugal |
Food and beverage processing other application |
Mining mineral and metal fan |
Mining mineral and metal pump |
Oil and gas fan |
Water and waste water other application |
Building – HVAC screw compressor |
Food and beverage processing pump |
Food and beverage processing fan |
Food and beverage processing atomization |
Oil and gas electro submersible pump (ESP) |
Oil and gas water injection pump |
Oil and gas jet fuel pump |
Oil and gas compressor for refinery |
Water and waste water centrifuge pump |
Water and waste water positive displacement pump |
Water and waste water electro submersible pump (ESP) |
Water and waste water screw pump |
Water and waste water lobe compressor |
Water and waste water screw compressor |
Water and waste water compressor centrifugal |
Water and waste water fan |
Water and waste water conveyor |
Water and waste water mixer |
Motor power range AC-3 |
250…500 kW 380…440 V 3 phase |
250…500 kW 480…500 V 3 phase |
Quantity per Set |
1 |
enclosure mounting |
Wall mounted |