Main |
Device short name |
ATV212 |
Product destination |
Asynchronous motors |
Phase |
3 phase |
Motor power kW |
37 kW |
Maximum Horse Power Rating |
50 hp |
Supply voltage limits |
323…528 V |
Supply frequency |
50…60 Hz – 5…5 % |
Line current |
68.9 A 380 V |
54.4 A 480 V |
Range of Product |
Altivar 212 |
Product or Component Type |
Variable speed drive |
Product Specific Application |
Pumps and fans in HVAC |
Communication Port Protocol |
METASYS N2 |
BACnet |
Modbus |
APOGEE FLN |
LonWorks |
[Us] rated supply voltage |
380…480 V – 15…10 % |
EMC filter |
Class C2 EMC filter integrated |
IP degree of protection |
IP21 |
Complementary |
Apparent power |
52 kVA 380 V |
Continuous output current |
79 A 380 V |
79 A 460 V |
Maximum transient current |
86.9 A 60 s |
Speed drive output frequency |
0.5…200 Hz |
Speed range |
1…10 |
Speed accuracy |
+/- 10 % of nominal slip 0.2 Tn to Tn |
Local signalling |
for DC bus energized 1 LED (red) |
Output voltage |
<= power supply voltage |
Isolation |
Electrical between power and control |
Type of cable |
Without mounting kit 1 IEC cable 113 °F (45 °C), copper 90 °C / XLPE/EPR |
Without mounting kit 1 IEC cable 113 °F (45 °C), copper 70 °C / PVC |
With UL Type 1 kit 3 UL 508 cable 104 °F (40 °C), copper 75 °C / PVC |
Electrical connection |
VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 0.004 in² (2.5 mm²) / AWG 14 |
L1/R, L2/S, L3/T terminal 0.08 in² (50 mm²) / AWG 1/0 |
Tightening torque |
5.3 lbf.in (0.6 N.m) VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES) |
212.4 lbf.in (24 N.m), 212 lb.in L1/R, L2/S, L3/T) |
Supply |
Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 A overload and short-circuit protection |
Internal supply 24 V DC 21…27 V), <200 A overload and short-circuit protection |
Sampling duration |
2 ms +/- 0.5 ms F discrete |
2 ms +/- 0.5 ms R discrete |
2 ms +/- 0.5 ms RES discrete |
3.5 ms +/- 0.5 ms VIA analog |
22 ms +/- 0.5 ms VIB analog |
Response time |
FM 2 ms +/- 0.5 ms analog |
FLA, FLC 7 ms +/- 0.5 ms discrete |
FLB, FLC 7 ms +/- 0.5 ms discrete |
RY, RC 7 ms +/- 0.5 ms discrete |
Accuracy |
+/- 0.6 % VIA) for a temperature variation 60 °C |
+/- 0.6 % VIB) for a temperature variation 60 °C |
+/- 1 % FM) for a temperature variation 60 °C |
Linearity error |
VIA +/- 0.15 % of maximum value input |
VIB +/- 0.15 % of maximum value input |
FM +/- 0.2 % output |
Analogue output type |
FM switch-configurable voltage 0…10 V DC 7620 Ohm 10 bits |
FM switch-configurable current 0…20 mA 970 Ohm 10 bits |
Discrete output type |
Configurable relay logic FLA, FLC) NO – 100000 cycles |
Configurable relay logic FLB, FLC) NC – 100000 cycles |
Configurable relay logic RY, RC) NO – 100000 cycles |
Minimum switching current |
3 mA 24 V DC configurable relay logic |
Maximum switching current |
5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL, R) |
5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL, R) |
2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL, R) |
2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL, R) |
Discrete input type |
F programmable 24 V DC level 1 PLC 4700 Ohm |
R programmable 24 V DC level 1 PLC 4700 Ohm |
RES programmable 24 V DC level 1 PLC 4700 Ohm |
Discrete input logic |
Positive logic (source) F, R, RES), <= 5 V, >= 11 V |
Negative logic (sink) F, R, RES), >= 16 V, <= 10 V |
Dielectric strength |
3535 V DC between earth and power terminals |
5092 V DC between control and power terminals |
Insulation resistance |
>= 1 mOhm 500 V DC for 1 minute |
Frequency resolution |
Display unit 0.1 Hz |
Analog input 0.024/50 Hz |
communication service |
Read holding registers (03) 2 words maximum |
Monitoring inhibitable |
Write single register (06) |
Write multiple registers (16) 2 words maximum |
Time out setting from 0.1 to 100 s |
Read device identification (43) |
Option card |
Communication card LonWorks |
Power dissipation in W |
976 W |
Air flow |
88235.05 Gal/hr(US) (334 m3/h) |
Functionality |
Mid |
Specific application |
HVAC |
Variable speed drive application selection |
Building – HVAC compressor for scroll |
Building – HVAC fan |
Building – HVAC pump |
Motor power range AC-3 |
30…50 kW 380…440 V 3 phase |
30…50 kW 480…500 V 3 phase |
Motor starter type |
Variable speed drive |
Discrete output number |
2 |
Analogue input number |
2 |
Analogue input type |
VIA switch-configurable voltage 0…10 V DC 24 V max 30000 Ohm 10 bits |
VIB configurable voltage 0…10 V DC 24 V max 30000 Ohm 10 bits |
VIB configurable PTC probe 0…6 probes 1500 Ohm |
VIA switch-configurable current 0…20 mA 250 Ohm 10 bits |
Analogue output number |
1 |
Physical interface |
2-wire RS 485 |
Connector Type |
1 open style |
1 RJ45 |
Transmission Rate |
9600 bps or 19200 bps |
Transmission frame |
RTU |
Number of addresses |
1…247 |
Data format |
8 bits, 1 stop, odd even or no configurable parity |
Type of polarization |
No impedance |
Asynchronous motor control profile |
Flux vector control without sensor, standard |
Voltage/frequency ratio, 5 points |
Voltage/frequency ratio, 2 points |
Voltage/frequency ratio – Energy Saving, quadratic U/f |
Voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo) |
Torque accuracy |
+/- 15 % |
Transient overtorque |
120 % of nominal motor torque +/- 10 % 60 s |
Acceleration and deceleration ramps |
Linear adjustable separately from 0.01 to 3200 s |
Automatic based on the load |
Motor slip compensation |
Not available in voltage/frequency ratio motor control |
Automatic whatever the load |
Adjustable |
Switching frequency |
6…16 kHz adjustable |
8…16 kHz with derating factor |
Nominal switching frequency |
8 kHz |
Braking to standstill |
By DC injection |
Network Frequency |
47.5…63 Hz |
Prospective line Isc |
22 kA |
Protection type |
Overheating protection drive |
Thermal power stage drive |
Short-circuit between motor phases drive |
Input phase breaks drive |
Overcurrent between output phases and earth drive |
Overvoltages on the DC bus drive |
Break on the control circuit drive |
Against exceeding limit speed drive |
Line supply overvoltage and undervoltage drive |
Line supply undervoltage drive |
Against input phase loss drive |
Thermal protection motor |
Motor phase break motor |
With PTC probes motor |
Width |
9.4 in (240 mm) |
Height |
21.7 in (550 mm) |
Depth |
9.6 in (244 mm) |
Environment |
Pollution degree |
3 IEC 61800-5-1 |
IP degree of protection |
IP20 on upper part without blanking plate on cover IEC 61800-5-1 |
IP20 on upper part without blanking plate on cover IEC 60529 |
IP21 IEC 61800-5-1 |
IP21 IEC 60529 |
IP41 on upper part IEC 61800-5-1 |
IP41 on upper part IEC 60529 |
Vibration resistance |
1.5 mm 3…13 Hz)IEC 60068-2-6 |
1 gn 13…200 Hz)EN/IEC 60068-2-8 |
Shock resistance |
15 gn 11 ms IEC 60068-2-27 |
Environmental characteristic |
Classes 3C1 IEC 60721-3-3 |
Classes 3S2 IEC 60721-3-3 |
Noise level |
64 dB 86/188/EEC |
Operating altitude |
3280.84…9842.52 ft (1000…3000 m) limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m |
<= 3280.84 ft (1000 m) without derating |
Relative humidity |
5…95 % without condensation IEC 60068-2-3 |
5…95 % without dripping water IEC 60068-2-3 |
Ambient air temperature for operation |
14…104 °F (-10…40 °C) without derating) |
104…122 °F (40…50 °C) with derating factor) |
Operating position |
Vertical +/- 10 degree |
Product Certifications |
UL |
NOM 117 |
C-tick |
CSA |
marking |
CE |
Standards |
IEC 61800-3 environments 2 category C1 |
IEC 61800-3 environments 1 category C3 |
IEC 61800-3 category C3 |
IEC 61800-3 category C2 |
IEC 61800-3 |
IEC 61800-3 environments 1 category C1 |
IEC 61800-5-1 |
IEC 61800-3 environments 1 category C1 |
EN 61800-3 category C3 |
IEC 61800-3 environments 2 category C2 |
IEC 61800-3 category C2 |
IEC 61800-3 environments 2 category C1 |
IEC 61800-3 |
IEC 61800-3 environments 1 category C3 |
UL Type 1 |
IEC 61800-3 environments 2 category C3 |
IEC 61800-3 environments 1 category C2 |
EN 55011 class A group 1 |
IEC 61800-5-1 |
IEC 61800-3 environments 1 category C2 |
IEC 61800-3 environments 2 category C3 |
IEC 61800-3 environments 2 category C2 |
Assembly style |
With heat sink |
Electromagnetic compatibility |
Electrostatic discharge immunity test level 3 IEC 61000-4-2 |
Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 |
Electrical fast transient/burst immunity test level 4 IEC 61000-4-4 |
1.2/50 µs – 8/20 µs surge immunity test level 3 IEC 61000-4-5 |
Conducted radio-frequency immunity test level 3 IEC 61000-4-6 |
Voltage dips and interruptions immunity test IEC 61000-4-11 |
Regulation loop |
Adjustable PI regulator |
Ambient Air Temperature for Storage |
-13…158 °F (-25…70 °C) |
Ordering and shipping details |
Category |
US1CP4D22158 |
Discount Schedule |
CP4D |
GTIN |
3606480322563 |
Returnability |
Yes |
Country of origin |
US |